Image from Google Jackets

Inter-observer and intra-observer reliability of the Harris Hip Scoring System / Anne Kathleen B. Ganal-Antonio, Gregorio Marcelo S. Azores

Contributor(s): Subject(s): Online resources: Abstract: OBJECTIVE: The Harris hip score (HHS) is a 100-point scale for rating pain, function, absence of deformity, and range of motion. The purpose of this study is to assess the inter-observer and intra-observer reliability of the Harris hip score among senior orthopedic residents at the Philippine General Hospital. METHODS: Twenty-four hips from 20 patients were evaluated using the Harris hip score by four senior residents from the Department of Orthopedics, Philippine General Hospital. All patients were interviewed twice in the clinic and the reliability of the HHS was evaluated. RESULTS: The inter-observer coefficient of concordance (Kendall coefficient of concordance W) was 0.9 for both groups of observers. The intra-observer coefficients of concordance were 0.8, 1.0, 0.9, and 0.9, for the four observers. A 0 value indicates no concordance among a set of raters while a score of 1 indicates perfect concordance. Obtaining a score greater than 0.75 represents excellent level of agreement. CONCLUSION: We conclude that the Harris hip score has high interobserver and inter-observer reliability among senior Orthopedic residents at the Philippine General Hospital.
Hello from Record Display Customizations!
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Cover image Item type Current library Home library Collection Shelving location Call number Materials specified Vol info URL Copy number Status Notes Date due Barcode Item holds Item hold queue priority Course reserves
Journal Article DOH Central Library Electronic Resource Section J000079 (Browse shelf(Opens below)) Available D0001J000079

OBJECTIVE: The Harris hip score (HHS) is a 100-point scale for rating pain, function, absence of deformity, and range of motion. The purpose of this study is to assess the inter-observer and intra-observer reliability of the Harris hip score among senior orthopedic residents at the Philippine General Hospital.

METHODS: Twenty-four hips from 20 patients were evaluated using the Harris hip score by four senior residents from the Department of Orthopedics, Philippine General Hospital. All patients were interviewed twice in the clinic and the reliability of the HHS was evaluated.


RESULTS: The inter-observer coefficient of concordance (Kendall coefficient of concordance W) was 0.9 for both groups of observers. The intra-observer coefficients of concordance were 0.8, 1.0, 0.9, and 0.9, for the four observers. A 0 value indicates no concordance among a set of raters while a score of 1 indicates perfect concordance. Obtaining a score greater than 0.75 represents excellent level of agreement.

CONCLUSION: We conclude that the Harris hip score has high interobserver and inter-observer reliability among senior Orthopedic residents at the Philippine General Hospital.

In: Acta Medica Philippina, 2012 vol 46 (2) pages: 32-37

There are no comments on this title.

to post a comment.