Image from Google Jackets

Sensitivity of non-ophthalmic ultrasound probe in the localization of metallic intra-ocular foreign bodies / Jerome Mary S. Sarmiento

By: Subject(s): Abstract: Industrialization carries an increased stress to include ocular trauma. Yet in a not so highly urbanized locale, very sophisticated and expensive diagnostic instruments that help diagnosis and specific localization of intraocular foreign bodies are not currently available. A previous study made at Cebu Doctors Hospital Ultrasound Center using a non-opththalmic (a 5 Mhz rectal probe) in the detection of metallic intraocular foreign bodies using porcine eyes revealed a 100 sensitivity. In the study, the authors would like to determine the sensitivity using the same prove in the localization of metallic intraocular foreign bodies randomly placed in four quadrants in porcine eyes. A total of 75 eyes were used inthe study. Fifteen subjects eyes were used per quadrant plus the control group. The ultrasound probe was noted to be most sensitive at the antero-superior quadrant (93) (p0.05) and least sensitive at the postero-inferior quadrant (73) (p0.01). In the group with no foreign bodies (control), sensitivity was 73 (p0.01).
Hello from Record Display Customizations!
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Cover image Item type Current library Home library Collection Shelving location Call number Materials specified Vol info URL Copy number Status Notes Date due Barcode Item holds Item hold queue priority Course reserves
Journal Article DOH Central Library Electronic Resource Section J000267 (Browse shelf(Opens below)) Available D0001J000267

Industrialization carries an increased stress to include ocular trauma. Yet in a not so highly urbanized locale, very sophisticated and expensive diagnostic instruments that help diagnosis and specific localization of intraocular foreign bodies are not currently available. A previous study made at Cebu Doctors Hospital Ultrasound Center using a non-opththalmic (a 5 Mhz rectal probe) in the detection of metallic intraocular foreign bodies using porcine eyes revealed a 100
sensitivity. In the study, the authors would like to determine the sensitivity using the same prove in the localization of metallic intraocular foreign bodies randomly placed in four quadrants in porcine eyes. A total of 75 eyes were used inthe study. Fifteen subjects eyes were used per quadrant plus the control group. The ultrasound probe was noted to be most sensitive at the antero-superior quadrant (93) (p0.05) and least sensitive at the postero-inferior quadrant (73) (p0.01). In the group with no foreign bodies (control), sensitivity was 73 (p0.01).

Cebu Doctors' Proceedings, 1994 10 (2) pages 127-31