Precision of the 512-hertz tuning fork for air conduction test in adults / (Record no. 3464)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 02413nam a22002057a 4500 |
| 003 - CONTROL NUMBER IDENTIFIER | |
| control field | DOH |
| 005 - DATE AND TIME OF LATEST TRANSACTION | |
| control field | 20210312132105.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 210312b ||||| |||| 00| 0 eng d |
| 245 00 - TITLE STATEMENT | |
| Title | Precision of the 512-hertz tuning fork for air conduction test in adults / |
| Statement of responsibility, etc. | Neil Penaflor [and three others] |
| 520 3# - SUMMARY, ETC. | |
| Summary, etc. | One hundred randomly selected personnel of a tertiary hospital were recruited as subjects to determine the possibility of using a 512-hertz as a tool for mass hearing screening. The primary objective was to determine the sound intensity level generated by the 512-hz tuning fork when four different procedures were employed: 1. Wrist action alone with the generated sound measured 3 inches from the sensors of a sound level meter 2. Wrist action alone-sound measured 6 inches away 3. Combined wrist and elbow action-sound measured 3 inches away 4. Combined wrist and elbow action-sound measured 6 inches away Secondary objectives were: 1. To determine which among the four procedures produced the least variability of results 2. Determine whether results would vary according to sex and procedure Results showed that the mean sound intensity level generated by the four procedures measured in sound pressure level (SPL) and converted into hearing level (HL) were 48.47 db HL (44.81-52.55, range=7.74). The mean standard deviation was 4.11 db HL (2.67-4.46; range=1.59). The procedure employing wrist action alone with sound intensity measured 6 inches away had the least variability. Two-way analysis of variance showed that sex and procedures were determinants of the differences in test results (p.001 for both). Though the differences were statistically different, the magnitude of difference was less than 5 db HL. Such magnitude is however not considered clinically significant since it may be due to interest variability itself. Hence the narrow range of variability in mean results and corresponding small standard deviations indicate that the 512hz tuning fork has a good potential as a tool for mass hearing screening programs. Further studies are suggested to determine its reliability and applicability. |
| 580 ## - LINKING ENTRY COMPLEXITY NOTE | |
| Linking entry complexity note | Acta Medica Philippina, 1999 35 (3 & 4) pages 6-12 |
| 653 ## - INDEX TERM--UNCONTROLLED | |
| Uncontrolled term | 512-Hertz |
| 653 ## - INDEX TERM--UNCONTROLLED | |
| Uncontrolled term | Mass Hearing Screening |
| 700 1# - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Penaflor, Neil |
| 700 1# - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Llanes, Eris |
| 700 1# - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Hilario, Oscar |
| 700 1# - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Abes, Generoso T |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Koha item type | Journal Article |
| 999 ## - | |
| -- | 3464 |
| -- | 3464 |
| Withdrawn status | Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Home library | Current library | Shelving location | Date acquired | Total Checkouts | Full call number | Barcode | Date last seen | Price effective from | Koha item type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| National Library of Medicine | DOH Central Library | DOH Central Library | Electronic Resource Section | 03/12/2021 | J000150 | D0001J000150 | 03/12/2021 | 03/12/2021 | Journal Article |