Image from Google Jackets

Comparison of the hybrid locking plate, standard dynamic compression plate, and standard dynamic compression plate augmented with bone cement for fixation of osteoporotic humeral shaft fractures : a cadaveric biomechanical study / Irewin A. Tabu [and two others]

Contributor(s): Subject(s): Online resources: Abstract: BACKGROUND: Studies comparing the relative strength of polymethylmethacrylate (PMMA) augmented fixation, standard plating and locked compression plate (LCP) system are few. The use of either the bone cement-augmented dynamic compression plate or the Hybrid LCP constructs may provide an additional tool for the treatment of fractures in patients with osteoporosis. METHODS: Eighteen (18) osteoporotic cadaveric humeral bones were assigned randomly to each of three groups (Dynamic Compression Plate [DCP], DCP augmented with bone cement, and the Hybrid LCP system) and tested in anterior-posterior bending and torsion/external rotation. The load to failure values were obtained and the results for each specimen compared. RESULTS: Significant differences were observed between the standard DCP and Hybrid LCP group (p-value=0.012), and in the cement-augmented and Hybrid LCP group (p-value=0.099) in torsion/external rotation loading. No significant difference was observed between the standard DCP and bone-cement augmented group (p-value=0.248). No significant difference was observed among the three groups in terms of stiffness (p-value=0.3868) in the four-point anterior-posterior bending modality. Screw pull-out of the implant was observed only in the regular DCP group in torsion/external rotation loading stress. CONCLUSION: Significant differences were seen between the three constructs in torsion/external rotation but not in anterior-posterior four-point bending. Bone failure, but not screw pull-out, was seen in the Hybrid LCP and bone cement-augmented DCP groups in torsion. This study showed that the LCP system and the bone cement-augmented constructs may provide greater screw purchase to the osteoporotic humerus.
Hello from Record Display Customizations!
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Cover image Item type Current library Home library Collection Shelving location Call number Materials specified Vol info URL Copy number Status Notes Date due Barcode Item holds Item hold queue priority Course reserves
Journal Article DOH Central Library Electronic Resource Section J000078 (Browse shelf(Opens below)) Available D0001J000078

BACKGROUND: Studies comparing the relative strength of polymethylmethacrylate (PMMA) augmented fixation, standard plating and locked compression plate (LCP) system are few. The use of either the bone cement-augmented dynamic compression plate or the Hybrid LCP constructs may provide an additional tool for the treatment of fractures in patients with osteoporosis.


METHODS: Eighteen (18) osteoporotic cadaveric humeral bones were assigned randomly to each of three groups (Dynamic Compression Plate [DCP], DCP augmented with bone cement, and the Hybrid LCP system) and tested in anterior-posterior bending and torsion/external rotation. The load to failure values were obtained and the results for each specimen compared.


RESULTS: Significant differences were observed between the standard DCP and Hybrid LCP group (p-value=0.012), and in the cement-augmented and Hybrid LCP group (p-value=0.099) in torsion/external rotation loading. No significant difference was observed between the standard DCP and bone-cement augmented group (p-value=0.248). No significant difference was observed among the three groups in terms of stiffness (p-value=0.3868) in the four-point anterior-posterior bending modality. Screw pull-out of the implant was observed only in the regular DCP group in torsion/external rotation loading stress.


CONCLUSION: Significant differences were seen between the three constructs in torsion/external rotation but not in anterior-posterior four-point bending. Bone failure, but not screw pull-out, was seen in the Hybrid LCP and bone cement-augmented DCP groups in torsion. This study showed that the LCP system and the bone cement-augmented constructs may provide greater screw purchase to the osteoporotic humerus.

In: Acta Medica Philippina, 2012 vol 46 (2) pages: 24-31

There are no comments on this title.

to post a comment.